As long as you need the exam, we can update the HP certification HP0-P19 exam training materials to meet your examination needs. Pass4Test's training materials contain many practice questions and answers about HP HP0-P19 and they can 100% ensure you pass HP HP0-P19 exam. With the training materials we provide, you can take a better preparation for the exam. And we will also provide you a year free update service.
Those who want to prepare for the IT certification exam are helpless. But they have to do it. So they have restless state of mind. However, With Pass4Test HP HP0-P19 exam training materials, the kind of mentality will disappear. With Pass4Test's HP HP0-P19 exam training materials, you can be brimming with confidence, and do not need to worry the exam. Of course, you can also face the exam with ease. This is not only psychological help, but more importantly, it allows you to pass the exam and to help you get a better tomorrow.
You can free download part of Pass4Test's practice questions and answers about HP certification HP0-P19 exam online. Once you decide to select Pass4Test, Pass4Test will make every effort to help you pass the exam. If you find that our exam practice questions and answers is very different form the actual exam questions and answers and can not help you pass the exam, we will immediately 100% full refund.
In the era of rapid development in the IT industry, we have to look at those IT people with new eyes. They use their high-end technology to create many convenient place for us. And save a lot of manpower and material resources for the state and enterprises. And even reached unimaginable effect. Of course, their income must be very high. Do you want to be the kind of person? Do you envy them? Or you are also IT person, but you do not get this kind of success. Do not worry, Pass4Test's HP HP0-P19 exam material can help you to get what you want. To select Pass4Test is equivalent to choose a success.
Exam Code: HP0-P19
Exam Name: HP (HP-UX High Availability Using Serviceguard v18)
One year free update, No help, Full refund!
Total Q&A: 145 Questions and Answers
Last Update: 2013-12-15
In the recent few years, HP HP0-P19 exam certification have caused great impact to many people. But the key question for the future is that how to pass the HP HP0-P19 exam more effectively. The answer of this question is to use Pass4Test's HP HP0-P19 exam training materials, and with it you can pass your exams. So what are you waiting for? Go to buy Pass4Test's HP HP0-P19 exam training materials please, and with it you can get more things what you want.
As we all know, the main problem is a lack of quality and utility in the IT fields. How to get you through the HP HP0-P19 certification exam? We need choose high quality learning information. Pass4Test will provide all the materials for the exam and free demo download. Like the actual certification exam, multiple choice questions (MCQ) help you pass the exam. Our HP HP0-P19 Exam will provide you with exam questions with verified answers that reflect the actual exam. These questions and answers provide you with the experience of taking the actual test. High quality and Value for the HP0-P19 Exam: 100% guarantee to Pass Your HP Business Solutions HP0-P19 exam and get your HP Business Solutions Certification.
HP0-P19 Free Demo Download: http://www.pass4test.com/HP0-P19.html
NO.1 Which situations does Serviceguard provide high availability solutions for? (Select two.)
A. LAN card failure
B. application failure
C. client subnet goes down
D. poor application performance
E. failure of one of the LUN paths to shared storage
Answer: AB
HP HP0-P19 HP0-P19 test questions HP0-P19 demo HP0-P19
NO.2 What are the main features of OL* (OnLine Replacement, Addition, and Deletion)? (Select two.)
A. ability to replace a cell board on an HP-UX system that supports OL*
B. ability to repair a PCI I/O card on an HP-UX system that supports OL*
C. ability to online replace a PCI I/O card on an HP-UX system that supports OL*
D. ability to online remove a PCI(-X) card on an HP-UX system that supports OL*
E. ability to online replace an HP-UX system that supports OL* while it is configured in a Serviceguard
cluster
F. ability to online remove a PCI(-X) LAN card and afterwards to online add a PCI(-X) FC HBA in the same
PCI(-X) slot on an HP-UX system that supports OL*
Answer: CD
HP HP0-P19 demo HP0-P19 HP0-P19 test
NO.3 What is the function of the lock disk or Quorum server in a Serviceguard cluster?
A. prevents split brain syndrome
B. determines which node becomes the cluster coordinator
C. ensures that quorum is present the entire time the cluster is up
D. keeps a record of volume groups that are locked in exclusive mode
Answer: A
HP practice test HP0-P19 pdf HP0-P19 HP0-P19 HP0-P19
NO.4 Your customer wants you to design an HA solution with HP-UX and Serviceguard that runs the
customer's Business Critical SAP production system as Serviceguard package, pkgA, and the customer's
Development SAP system as Serviceguard package, pkgB.
You design two vPars (vpar1 and vpar2) on serverA and two vPars (vpar3 and vpar4) on serverB.
What is a good design for this cluster to provide the maximum high availability? (Select two.)
A. Cluster vpar1 and vpar2 and run pkgA on these clustered vPars.
B. Cluster vpar1 and vpar3 and run pkgA on these clustered vPars.
C. Cluster vpar2 and vpar4 and run pkgB on these clustered vPars.
D. Cluster vpar3 and vpar4 and run pkgB on these clustered vPars.
Answer: BC
HP HP0-P19 HP0-P19 certification training HP0-P19
NO.5 Which failure scenarios are transparent to application users when the application is running as a
Serviceguard package? (Select two.)
A. A LAN interface fails on a node where no package is running.
B. A complete power outage in the computer room where the cluster is located.
C. A redundant power supply fails in the cluster node running the application package.
D. Manual application package switch because of planned downtime on the cluster node.
E. The cluster node running the application package crashes because of a memory multibit error.
Answer: AC
HP HP0-P19 dumps torrent HP0-P19 HP0-P19 HP0-P19
NO.6 In which situations can a local high availability solution prevent unplanned downtime? (Select two.)
A. An operator accidentially reboots a cluster node.
B. The shared storage component looses A/C power and goes down.
C. A complete data center goes down because of an environmental disaster.
D. The network communication between the cluster nodes is permanently interrupted.
E. The clustered application database becomes corrupted by installation of an application patch.
Answer: AD
HP HP0-P19 HP0-P19 HP0-P19
NO.7 Which components are considered potential single points of failure within a single HP-UX server?
(Select four.)
A. SAN
B. memory
C. backplane
D. DVD drive
E. LAN interfaces
F. mirrored root disks
G. system adminstrator
H. redundant power supply
I. Fibre Channel Host Bus Adapter
Answer: BCEI
HP exam simulations HP0-P19 dumps torrent HP0-P19 test answers
NO.8 Which products offer a solution to protect from failure of a complete data center? (Select three.)
A. Metrocluster
B. Serviceguard
C. Continentalclusters
D. Extended Campus Cluster
E. Enterprise Cluster Master Toolkit
Answer: ACD
HP pdf HP0-P19 HP0-P19
NO.9 What are potential single points of failure (SPOF) in an HP-UX environment? (Select two.)
A. backplane of a cell based server when two vPARs are clustered with Serviceguard over two physical
nodes
B. backplane of a cell based server when two vPARs are clustered with Serviceguard on the same
physical node
C. cellboard on a partioned node with two nPARs that are clustered with Serviceguard on the same
physical node
D. cellboard on a single-nPar node with two vPARs that are clustered with Serviceguard on the same
physical node
Answer: BD
HP HP0-P19 dumps torrent HP0-P19 HP0-P19
NO.10 Which application templates are included in the Enterprise Cluster Master Toolkit (ECMT)? (Select
four.)
A. NFS
B. SAP
C. SAPDB
D. HP Tomcat
E. HP Apache
F. HP CIFS/9000
G. Oracle 9i and 10g
Answer: DEFG
HP practice test HP0-P19 answers real questions HP0-P19 HP0-P19
NO.11 In the context of high availability, which phrase describes Mean Time Between Failure (MTBF)?
A. mean time to restart a failed service
B. mean time to repair a server after a failure
C. mean time to restart a server after a failure
D. mean time a system provides service without failure
Answer: D
HP exam HP0-P19 HP0-P19 HP0-P19 exam dumps
NO.12 What does OL* (OnLine Replacement, Addition, and Deletion) provide?
A. online replacement, addtion, and deletion of vPARs
B. online replacement, addition, and deletion of PCI(-X) I/O cards
C. online replacement, addition, and deletion of cell boards in cell based systems
D. online replacement, addition, and deletion of PCI(-X) I/O cards and core I/O cards
Answer: B
HP HP0-P19 HP0-P19 HP0-P19 dumps torrent
NO.13 Click the Exhibit button.
Based on the cmviewcl output, which statement is correct?
A. A failure of ora_lsnr will cause alien_pkg to failover.
B. A single failure of oracle9i will cause alien_pkg to failover.
C. The subnet 192.168.1.0 going down will cause alien_pkg to failover.
D. A failure of either ora_lsnr or oracle9i will cause alien_pkg to failover.
Answer: C
HP HP0-P19 original questions HP0-P19 HP0-P19 certification
NO.14 In the context of high availability, which statements are true regarding split-brain syndrome? (Select
two.)
A. It can occur on a 2-node cluster.
B. It can occur on a 3-node cluster.
C. It allows different applications to simulatneously access the same disk.
D. It allows different partitions to access the same disk without knowledge of each other.
E. It is caused when two clusters initiate an application that accesses the same disk simultaneously.
F. It is caused when two equal size sub-clusters form from a single cluster without knowledge of each
other.
Answer: AF
HP test answers HP0-P19 practice test HP0-P19 exam HP0-P19 exam simulations
NO.15 When implementing a legacy package utilizing application monitoring, which variable in the package
control script will point to the monitor script?
A. service_cmd
B. SERVICE_CMD
C. MONITOR_CMD
D. MONITOR_NAME
Answer: B
HP HP0-P19 exam simulations HP0-P19 test answers HP0-P19 HP0-P19 practice test
NO.16 A customer has a 2-node HP Serviceguard cluster running a mission critical Oracle database and a
financial application. At the end of each month the server utilization spikes with no idle CPU resources
and there is a need for additional capacity.
Which HP Virtual Server Environment offering provides additional capacity and is best in this situation?
A. Capacity Advisor
B. Instant Capacity (iCAP)
C. Integrity Virtual Machines
D. Global Workload Manager (gWLM)
E. Temporary Instant Capacity (TiCAP)
Answer: E
HP HP0-P19 practice test HP0-P19 test answers HP0-P19 practice test HP0-P19 pdf HP0-P19 dumps
NO.17 In a Serviceguard implementation for concurrent instances of an Oracle RAC Database, which type of
shared storage management can be used on all nodes in the cluster? (Select three.)
A. Cluster File System (CFS)
B. Veritas Volume Manager (VxVM)
C. Network Attached Storage (NAS)
D. Shared Logical Volume Manager (SLVM)
E. Standard Logical Volume Manager (LVM)
F. Enterprise Logical Volume Manager (ELVM)
G. Oracle Automatic Storage Management (ASM)
Answer: ADG
HP certification HP0-P19 HP0-P19 answers real questions HP0-P19 questions HP0-P19 exam prep HP0-P19
NO.18 You are asked by your management team to do a presentation and explain why your IT department
should go with the SGeRAC solution instead of the standard single-instance Oracle implementation with
Serviceguard.
Which benefits should you present? (Select two.)
A. reduces the overall cost
B. increases the security level
C. provides easier cluster management
D. reduces recovery time of a large database
E. provides the ability to add more nodes to the cluster on the fly
F. increases processing power without the need to administer separate databases
Answer: DF
HP HP0-P19 HP0-P19 HP0-P19 HP0-P19 HP0-P19 pdf
NO.19 Which configurations are valid for a Serviceguard environment in combination with Integrity Virtual
machines? (Select two.)
A. Configuration 1
B. Configuration 2
C. Configuration 3
D. Configuration 4
Answer: AB
HP questions HP0-P19 dumps HP0-P19
NO.20 Which statement is correct concerning the difference between a local Serviceguard cluster and an
extended distance cluster (also known as a campus cluster)?
A. An extended distance cluster provides disaster tolerance across two data centers located on different
continents.
B. An extended distance cluster solution typically requires a physical data replication mechanism between
high end storage arrays.
C. An extended distance cluster solution typically uses host based disk mirroring between two computer
rooms in an IT environment.
D. An extended distance cluster is a separate product installation to implement High Availability between
two computer rooms in a IT environment.
Answer: C
HP original questions HP0-P19 HP0-P19 HP0-P19 original questions HP0-P19
NO.21 Which statements are true regarding Serviceguard Manager version 5.01? (Select three.)
A. Serviceguard Manager is a graphical user interface for the Serviceguard product.
B. With Serviceguard Manager you can monitor, administer, and configure clusters managed by
Serviceguard.
C. With Serviceguard Manager you can run a multinode cluster which consists of both HP-UX and Linux
nodes.
D. With Serviceguard Manager you can change package-switching and node-switching flags for failover
packages.
E. With Serviceguard Manager you can install Serviceguard software product on hosts managed by HP
Systems Insight Manager (HP SIM).
Answer: ABD
HP HP0-P19 HP0-P19 HP0-P19 test questions
NO.22 What are advantages of RAC cluster? (Select three.)
A. increases user scalability
B. increases database security
C. supports larger database size
D. increases hardware scalability
E. increases database availability
F. increases application scalability
G. decreases package failover time
Answer: DEF
HP HP0-P19 HP0-P19 HP0-P19
NO.23 What is the purpose of the cluster interconnect in a Serviceguard extension for Oracle RAC
implementation? (Select two.)
A. Nodes can use it for cluster heartbeat traffic.
B. Nodes coordinate the shared storage status.
C. Oracle single instances coordinate their online/offline status.
D. Oracle RAC instances coordinate the consistency between their Oracle buffer cache.
Answer: AD
HP HP0-P19 HP0-P19 certification HP0-P19 demo HP0-P19 original questions
NO.24 What are the advantages with respect to application availability for a customer using Serviceguard in
an HA environment? (Select two.)
A. Application database corruptions will be minimized.
B. An upgrade of the operating system will only require a package switch.
C. A power outage in the customer's computer room will not affect the users.
D. Rolling upgrades of the application can be performed in a Serviceguard environment.
E. A failure in a redundant power supply will only cause a package switch to the adoptive node.
Answer: BD
HP HP0-P19 HP0-P19 HP0-P19 dumps torrent
NO.25 When a Serviceguard package fails over in a highly available vPar environment, Workload Manager
(WLM) integrates with Serviceguard and disaster tolerant solutions by doing which process?
A. WLM creates a new vPar to assume the load of the failed partition.
B. cmcld creates a new vPar to assume the load of the failed partition.
C. WLM moves processor resources from one virtual partition to another.
D. cmcld moves processor resources from one virtual partition to another.
E. WLM can move a Serviceguard package from one virtual partition to another.
Answer: C
HP braindump HP0-P19 answers real questions HP0-P19 practice test
NO.26 In the context of high availability, which phrase describes Mean Time To Repair (MTTR)?
A. mean interval of time to resume a service after a failure
B. mean time a service engineer needs to repair a failed server
C. mean interval of time when the system provides service without fault
D. mean time a service engineer needs to replace a server after a failure
E. mean time a service engineer needs to arrive at the site of a failed server
Answer: A
HP dumps torrent HP0-P19 HP0-P19 exam HP0-P19
NO.27 Which statements are true regarding High Availability (HA)? (Select three.)
A. Downtime is any amount of time when the application is unavailable (planned or unplanned).
B. HA systems provide a disaster tolerant solution that allows recovery from the loss of an entire data
center.
C. Unplanned downtime is be caused by a failure of a non-redundant hardware component on a cluster
node.
D. Metrocluster and Extended Campus Cluster solutions provide the same level of protection as a local
HA solution in case of environmental disasters.
E. HA is a combination of environmental, process, software, and computing hardware enhancements that
maximize the time that the application and system are available.
F. Highly available systems typically contain data redundancy through mirroring or RAID, some kind of
backup system hardware, power outage protection, and multiple LANs.
Answer: AEF
HP HP0-P19 test HP0-P19 HP0-P19
NO.28 Consider the following entry in the /etc/rc.config.d/cmcluster file.
AUTOSTART_CMCLD=1
Which parameter in the cluster ascii file is affected by this entry?
A. CMCLD_TIMEOUT
B. CMCLD_RUN_START
C. AUTOSTART_CMCLD
D. AUTOSTART_TIMEOUT
E. HEARTBEAT_INTERVAL
Answer: D
HP HP0-P19 dumps HP0-P19
NO.29 An e-ticketing application based on Apache webserver for a busy tourist market experiences failures
during peak season, resulting in loss of revenues.
Which product combination implements a solution that improves availability of the e-ticketing application?
(Select two.)
A. HP Serviceguard
B. Continental Clusters
C. HP Serviceguard Extension for SAP
D. Enterprise Cluster Master Toolkit
E. HP Serviceguard Extension for RAC
Answer: AD
HP braindump HP0-P19 HP0-P19 HP0-P19 certification training
NO.30 What are potential single points of failure (SPOF) in an HP-UX system? (Select four.)
A. hard disk drive
B. operating system
C. system administrator
D. redundant power supply
E. CPU on a Uniprocessor system
F. multi-port network interface card
G. alternate link to a disk in a shared volume group
Answer: ABEF
HP HP0-P19 certification training HP0-P19 braindump HP0-P19 HP0-P19 dumps torrent
Pass4Test offer the latest IIA-CIA-Part3 exam material and high-quality 70-460 pdf questions & answers. Our 000-656 VCE testing engine and C-TFIN52-64 study guide can help you pass the real exam. High-quality 1z0-465 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.pass4test.com/HP0-P19.html
没有评论:
发表评论